B1
The battery icon flashes with one bar, and the unit beeps, then shuts off quickly.
Low Battery Warning / Deep Discharge Protection
B2
The battery icon flashes with two bars, and the unit will not enter turbo mode.
Battery Current Limit / Protection Threshold
E1
Cordless vacuum will not power on; the red LED flashes once repeatedly when the power button is pressed.
Battery Pack Undervoltage Lockout
E2
Cordless vacuum shuts off within a few seconds of starting; the LED flashes twice repeatedly.
Battery Overcurrent / Short Circuit Protection
E3
Cordless vacuum stops and the LED flashes three times repeatedly, often when using turbo or high power mode.
Motor Overheating Protection
E4
Cordless vacuum will not charge; the charger LED blinks or the vacuum LED flashes four times when placed on the charger.
Battery Temperature Out of Range
E5
Cordless vacuum will not charge; the charger LED remains off or flashes five times, with no battery level indication.
Charger / Dock Communication Failure
E6
Cordless vacuum runs only on low power, will not switch to high/turbo. The LED flashes six times when high mode is selected.
High-Speed Motor Drive Fault
E7
The brushroll in the motorized floor head does not spin. The handle LEDs flash seven times when the floor nozzle is attached.
Brushroll Motor Overload / Stall Protection
E8
The cordless vacuum LEDs flash eight times, and the unit shuts off when the wand or accessories are attached, but it runs briefly in handheld mode.
Accessory / Wand Connection Fault
E9
All LEDs flash rapidly, and the vacuum will not start, even with a known-good battery.
Main Control Board Fault / Firmware Error
F1
The battery indicator shows full, but the vacuum stops abruptly under load and flashes a single red bar or F1 icon.
Battery Capacity Degradation
F2
The filter warning icon or F2 appears, suction is weak, and the unit may pulse on and off.
Filter Blockage / Filter Sensor Triggered
F3
The LED or display shows F3, and the vacuum will not start, often after a drop or impact.
Internal Fault / Impact Sensor Triggered
F4
The charging icon flashes with F4, and the battery does not gain charge.
Charge Overvoltage / Wrong Charger Detected
Symptom
Brushroll does not spin, but suction is present.
Brushroll Drive Failure
Symptom
Cordless vacuum will not turn on at all; no lights or sounds.
No Power / Dead Unit
Symptom
Dirt or dust leaks from joints or around the filter area during use.
Air Seal/Gasket Failure
Symptom
The LED battery indicator does not change or is inaccurate (e.g., shows full then suddenly empty).
Battery Fuel Gauge Calibration Error
Symptom
The dirt cup will not latch securely or falls off during use.
Dust Cup Latch Failure
Symptom
The powered mini turbo tool (pet tool) does not spin when attached, but the main floor head works.
Accessory Motor/Connection Failure
Symptom
The vacuum body or handle creaks and flexes excessively during use.
Housing/Chassis Fatigue
Symptom
The vacuum produces a musty or unpleasant odor from the exhaust air.
Odor Contamination in Filters and Dirt Path
Symptom
The vacuum produces an unusual electrical buzzing or crackling sound near the charger port while charging.
Charging Port/Connector Arcing
Symptom
The vacuum will not stand upright on its own (for stick models designed to self-stand).
Parking Lock/Stand Mechanism Failure
Symptom
The vacuum will not stay on the wall mount or dock, falls off easily, and sometimes does not charge.
Docking/Mounting Misalignment
Symptom
The vacuum's runtime is much shorter than specified, even after a full charge.
Reduced Battery Capacity/High Load
Symptom
Vacuum emits a burning smell during use.
Electrical Overheating / Component Failure
Symptom
Vacuum handle or body becomes uncomfortably hot where you hold it.
Localized Overheating / Poor Heat Dissipation
Symptom
Vacuum hose collapses or kinks easily, reducing suction.
Hose Structural Failure
Symptom
Vacuum leaves lines of debris behind and does not pick up well from carpet.
Poor Agitation / Worn Brushroll
Symptom
Vacuum makes a grinding or rattling noise from the floor nozzle when the brushroll is engaged.
Brushroll Bearing or Gear Damage
Symptom
Vacuum powers on but has very weak suction; motor sounds normal.
Airflow Restriction / Loss of Suction
Symptom
Vacuum pulses on and off repeatedly while running, especially on carpet.
Cyclone / Filter Restriction Causing Motor Surging
Symptom
Vacuum runs but makes a loud, high-pitched whine from the main body.
Suction Motor Bearing Wear
Symptom
Vacuum runs only intermittently when the trigger is held, cutting in and out with slight handle movement.
Intermittent Power / Loose Electrical Connection
Symptom
Vacuum shuts off after a few minutes of use and feels hot to the touch.
Thermal Overload Trip
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| B1 |
The battery icon flashes with one bar, and the unit beeps, then shuts off quickly.
|
Low Battery Warning / Deep Discharge Protection | View Details |
| B2 |
The battery icon flashes with two bars, and the unit will not enter turbo mode.
|
Battery Current Limit / Protection Threshold | View Details |
| E1 |
Cordless vacuum will not power on; the red LED flashes once repeatedly when the power button is pressed.
|
Battery Pack Undervoltage Lockout | View Details |
| E2 |
Cordless vacuum shuts off within a few seconds of starting; the LED flashes twice repeatedly.
|
Battery Overcurrent / Short Circuit Protection | View Details |
| E3 |
Cordless vacuum stops and the LED flashes three times repeatedly, often when using turbo or high power mode.
|
Motor Overheating Protection | View Details |
| E4 |
Cordless vacuum will not charge; the charger LED blinks or the vacuum LED flashes four times when placed on the charger.
|
Battery Temperature Out of Range | View Details |
| E5 |
Cordless vacuum will not charge; the charger LED remains off or flashes five times, with no battery level indication.
|
Charger / Dock Communication Failure | View Details |
| E6 |
Cordless vacuum runs only on low power, will not switch to high/turbo. The LED flashes six times when high mode is selected.
|
High-Speed Motor Drive Fault | View Details |
| E7 |
The brushroll in the motorized floor head does not spin. The handle LEDs flash seven times when the floor nozzle is attached.
|
Brushroll Motor Overload / Stall Protection | View Details |
| E8 |
The cordless vacuum LEDs flash eight times, and the unit shuts off when the wand or accessories are attached, but it runs briefly in handheld mode.
|
Accessory / Wand Connection Fault | View Details |
| E9 |
All LEDs flash rapidly, and the vacuum will not start, even with a known-good battery.
|
Main Control Board Fault / Firmware Error | View Details |
| F1 |
The battery indicator shows full, but the vacuum stops abruptly under load and flashes a single red bar or F1 icon.
|
Battery Capacity Degradation | View Details |
| F2 |
The filter warning icon or F2 appears, suction is weak, and the unit may pulse on and off.
|
Filter Blockage / Filter Sensor Triggered | View Details |
| F3 |
The LED or display shows F3, and the vacuum will not start, often after a drop or impact.
|
Internal Fault / Impact Sensor Triggered | View Details |
| F4 |
The charging icon flashes with F4, and the battery does not gain charge.
|
Charge Overvoltage / Wrong Charger Detected | View Details |
| – |
Brushroll does not spin, but suction is present.
|
Brushroll Drive Failure | View Details |
| – |
Cordless vacuum will not turn on at all; no lights or sounds.
|
No Power / Dead Unit | View Details |
| – |
Dirt or dust leaks from joints or around the filter area during use.
|
Air Seal/Gasket Failure | View Details |
| – |
The LED battery indicator does not change or is inaccurate (e.g., shows full then suddenly empty).
|
Battery Fuel Gauge Calibration Error | View Details |
| – |
The dirt cup will not latch securely or falls off during use.
|
Dust Cup Latch Failure | View Details |
| – |
The powered mini turbo tool (pet tool) does not spin when attached, but the main floor head works.
|
Accessory Motor/Connection Failure | View Details |
| – |
The vacuum body or handle creaks and flexes excessively during use.
|
Housing/Chassis Fatigue | View Details |
| – |
The vacuum produces a musty or unpleasant odor from the exhaust air.
|
Odor Contamination in Filters and Dirt Path | View Details |
| – |
The vacuum produces an unusual electrical buzzing or crackling sound near the charger port while charging.
|
Charging Port/Connector Arcing | View Details |
| – |
The vacuum will not stand upright on its own (for stick models designed to self-stand).
|
Parking Lock/Stand Mechanism Failure | View Details |
| – |
The vacuum will not stay on the wall mount or dock, falls off easily, and sometimes does not charge.
|
Docking/Mounting Misalignment | View Details |
| – |
The vacuum's runtime is much shorter than specified, even after a full charge.
|
Reduced Battery Capacity/High Load | View Details |
| – |
Vacuum emits a burning smell during use.
|
Electrical Overheating / Component Failure | View Details |
| – |
Vacuum handle or body becomes uncomfortably hot where you hold it.
|
Localized Overheating / Poor Heat Dissipation | View Details |
| – |
Vacuum hose collapses or kinks easily, reducing suction.
|
Hose Structural Failure | View Details |
| – |
Vacuum leaves lines of debris behind and does not pick up well from carpet.
|
Poor Agitation / Worn Brushroll | View Details |
| – |
Vacuum makes a grinding or rattling noise from the floor nozzle when the brushroll is engaged.
|
Brushroll Bearing or Gear Damage | View Details |
| – |
Vacuum powers on but has very weak suction; motor sounds normal.
|
Airflow Restriction / Loss of Suction | View Details |
| – |
Vacuum pulses on and off repeatedly while running, especially on carpet.
|
Cyclone / Filter Restriction Causing Motor Surging | View Details |
| – |
Vacuum runs but makes a loud, high-pitched whine from the main body.
|
Suction Motor Bearing Wear | View Details |
| – |
Vacuum runs only intermittently when the trigger is held, cutting in and out with slight handle movement.
|
Intermittent Power / Loose Electrical Connection | View Details |
| – |
Vacuum shuts off after a few minutes of use and feels hot to the touch.
|
Thermal Overload Trip | View Details |
No matching codes found
Advertisements