E03
Megear Ground Fault / Leakage Current Detected

Charger shows E03 and immediately stops or refuses to start charging; vehicle may briefly start then drop out.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Moisture inside J1772 connector, Damaged insulation in Megear charge cable, Faulty internal ground fault detection circuit, Contaminated or loose ground connection in supply wiring

How to Fix / Troubleshooting

Safety first: Disconnect the charger from power and do not use it if you suspect a ground fault. Water and electricity are extremely dangerous together.

  • 1. Inspect for moisture:
    • Check the J1772 connector for water, condensation, or dirt.
    • If wet, gently shake out excess water and allow the connector to dry completely in a warm, dry area for at least 24 hours.
  • 2. Examine the cable jacket:
    • Look for cuts, abrasions, or crushed sections along the Megear cable.
    • If copper conductors are visible or the cable feels soft/spongy from damage, the entire cable assembly must be replaced.
  • 3. Check ground connection:
    • Have a qualified electrician verify that the outlet or hardwired circuit has a solid equipment ground.
    • Tighten any loose ground screws in the outlet box (with power off).
  • 4. Internal GFCI board inspection (advanced):
    • With power disconnected, open the Megear housing.
    • Locate the ground fault detection (GFCI) board or circuitry on the main control board.
    • Look for burn marks, cracked components, or loose connectors on the current transformer (CT) ring that senses leakage.
    • If damaged, replace the main control board or GFCI module as a unit.

If E03 reappears after drying and inspection, discontinue use until the charger is evaluated by a qualified EVSE technician, as persistent ground faults can indicate serious safety issues.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Megear GFCI / Ground Fault Detection Circuit (Main Control Board)
Check Price on Amazon