F5
Amana Discharge Line Temperature Sensor Fault

The system displays F5; the compressor may be locked out or the system may run in a limited mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed discharge temperature sensor, sensor not clamped to the line, damaged wiring, or control board sensor circuit failure.

How to Fix / Troubleshooting

Safety first: Turn off power at the disconnect. The discharge line can be extremely hot; allow time to cool before touching.

Steps to address F5 (discharge temperature sensor):

  • Locate sensor: Find the sensor clipped to the compressor discharge line near the compressor outlet.
  • Check attachment: Ensure the sensor is firmly clamped to the copper line and insulated as originally installed. Re-secure if loose.
  • Inspect wiring: Look for heat-damaged insulation or loose connectors. Repair or replace damaged wiring.
  • Test sensor: Disconnect and measure resistance; compare to the Amana chart. Replace if out of specification.
  • Evaluate board: If the sensor is good and properly mounted but F5 remains, replace the control board.

Do not relocate the sensor away from the discharge line; it is critical for compressor overheat protection.