E6
Arctic King Communication Fault Between Display Board and Main PCB

Unit shows E6 and may not respond to remote commands or may not start certain functions.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or damaged communication cable, Corroded connector between display and main board, Failed display/control panel, Failed main control board

How to Fix / Troubleshooting

Safety: Disconnect power before removing the front panel or control box cover.

Steps to resolve E6:

  • Inspect control panel: Remove the front bezel to access the display/control board. Check for moisture, corrosion, or signs of liquid spills.
  • Check ribbon cable: Locate the ribbon or multi-wire harness connecting the display board to the main PCB. Reseat both ends by unplugging and firmly plugging them back in.
  • Look for damage: Inspect the cable for kinks, cuts, or crushed sections where the plastic housing may have pinched it. Replace the display-to-main-board harness if damaged.
  • Test operation: Reassemble enough to power the unit safely and test. If E6 clears, fully reassemble.
  • Board substitution: If E6 persists, either the display board or main PCB is likely faulty. Start by replacing the display/control panel board (often more accessible and less expensive). If that does not resolve the issue, replace the main control board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Display/Control Panel Board