E24
Baxi
Indoor Coil Freeze Protection / Low Evaporator Temperature
Indoor unit shows E24; the unit may stop after running for some time.
Advertisements
Possible Causes
Very dirty indoor filters, Blocked indoor coil, Low indoor fan speed due to a failing motor, Low refrigerant charge causing coil freeze
How to Fix / Troubleshooting
Safety: Turn off the unit before cleaning.
Steps:
- 1. Clean filters: Remove and wash indoor air filters with mild detergent. Dry completely before reinstalling.
- 2. Clean the evaporator coil: Use a soft brush or coil cleaner to remove dust from the indoor coil fins.
- 3. Check fan speed: Run the unit and verify that airflow is strong at all fan settings. Weak airflow may indicate a failing fan motor.
- 4. Observe for ice: If ice forms on the coil, turn off the unit and allow it to thaw. Persistent icing suggests low refrigerant or airflow issues, requiring a technician.