E24
Baxi Indoor Coil Freeze Protection / Low Evaporator Temperature

Indoor unit shows E24; the unit may stop after running for some time.

Advertisements

Possible Causes

Very dirty indoor filters, Blocked indoor coil, Low indoor fan speed due to a failing motor, Low refrigerant charge causing coil freeze

How to Fix / Troubleshooting

Safety: Turn off the unit before cleaning.

Steps:

  • 1. Clean filters: Remove and wash indoor air filters with mild detergent. Dry completely before reinstalling.
  • 2. Clean the evaporator coil: Use a soft brush or coil cleaner to remove dust from the indoor coil fins.
  • 3. Check fan speed: Run the unit and verify that airflow is strong at all fan settings. Weak airflow may indicate a failing fan motor.
  • 4. Observe for ice: If ice forms on the coil, turn off the unit and allow it to thaw. Persistent icing suggests low refrigerant or airflow issues, requiring a technician.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Indoor Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements