Coleman Insufficient Cooling Capacity / Underperformance

Coleman air conditioner runs but does not cool the space adequately; supply air feels only slightly cooler than room air.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge from leak in Coleman coil or line set, Dirty condenser coil, Dirty evaporator coil, Weak compressor on Coleman condenser unit

How to Fix / Troubleshooting

Safety: Turn OFF power before cleaning coils or opening panels. Refrigerant work must be done by a licensed technician.

  • Check filter and vents: Replace the air filter and ensure all supply and return vents are open and unobstructed.
  • Clean indoor coil: Access the evaporator coil in the Coleman air handler. Clean with an appropriate coil cleaner if dirty.
  • Clean outdoor coil: Remove debris and wash the condenser coil as described earlier.
  • Measure temperature drop: With the system running for 15–20 minutes, measure the temperature at a return grille and a nearby supply vent. A typical drop is 15–20°F. If much lower, airflow may be restricted; if much higher, refrigerant charge may be incorrect.
  • Call a technician for refrigerant issues: If coils are clean and airflow is good but cooling is still weak, a Coleman-certified technician should check refrigerant pressures, locate leaks, and recharge the system.

Note: Oversized or undersized equipment relative to the home can also cause comfort issues; a load calculation may be needed.