Comfortmaker Compressor Not Starting

Comfortmaker outdoor fan runs, but the compressor does not; no cooling.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor section of the dual run capacitor, Open compressor winding, Internal compressor overload open, Faulty contactor pole feeding the compressor.

How to Fix / Troubleshooting

Safety: Disconnect power at the outdoor disconnect before testing.

Steps:

  • Test dual run capacitor: Focus on the HERM (compressor) terminal. Replace the capacitor if out of spec.
  • Inspect wiring: Ensure all compressor leads are firmly attached and not burned.
  • Check contactor: Verify both poles are delivering voltage when energized.
  • Allow cool-down: If the compressor is very hot, let it cool for 1–2 hours and retry.

Technician required: If compressor windings test open/shorted or still will not start, compressor replacement may be needed.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Dual Run Capacitor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements