Keeprite Evaporator Coil Icing

Evaporator coil or suction line is covered in ice; little or no airflow from vents.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Very dirty air filter, Blower motor failure or low speed, Low refrigerant charge, Closed registers or blocked returns, Oversized system with short run times

How to Fix / Troubleshooting

Safety first: Turn off cooling at the thermostat to prevent compressor damage.

  • Step 1 – Thaw the system: Set thermostat to FAN ONLY and let it run until all ice melts. Do not chip ice off the coil.
  • Step 2 – Replace filter: Install a clean filter and ensure correct size and airflow rating.
  • Step 3 – Check blower: Verify the blower runs strongly in cooling mode. If weak or intermittent, have the motor and capacitor checked.
  • Step 4 – Open registers: Open all supply and return registers fully.
  • Step 5 – Technician check: If icing recurs, a technician should check refrigerant charge and system design.