E3
Pioneer Low-Pressure Protection / Refrigerant Undercharge or Flow Restriction

Indoor unit shows E3 and stops; outdoor unit may shut down shortly after starting

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Refrigerant leak in line set or coils, Clogged expansion device or capillary, Partially closed service valve, Severely iced evaporator coil

How to Fix / Troubleshooting

Safety first: Do not attempt to add refrigerant or open the sealed system unless you are certified. Turn off power before removing any covers.

Steps to try:

  • Inspect for ice: Remove the indoor front cover and check for ice on the evaporator coil or suction line. If present, turn the system OFF and run FAN-only mode for 30–60 minutes to melt ice.
  • Check air filters and airflow: Clean filters and ensure no supply or return vents are blocked. Poor airflow can mimic low-pressure conditions.
  • Look for oil stains: Examine flare connections at the indoor and outdoor units and along the line set for oily residue, which indicates a refrigerant leak.
  • Verify service valves are open (visual): Confirm valve stems are fully counterclockwise. Do not force them.

When to call a pro: Persistent E3 indicates a refrigerant-side problem. A technician must locate leaks, repair, evacuate, and recharge the system to Pioneer specifications.