F5
Trane
Compressor Temperature Sensor Fault
Trane air conditioner displays F5 and may not start the compressor; the system may run the fan only.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor thermistor, Sensor detached from compressor shell, Damaged sensor wiring, Control board sensor circuit failure
How to Fix / Troubleshooting
Safety first: Turn off power at the disconnect and allow the compressor to cool before touching.
- Locate sensor: The sensor is usually strapped or clipped to the compressor shell. Ensure it is firmly attached and not hanging loose.
- Inspect harness: Check the sensor wires for heat damage or abrasion against metal edges. Repair or reroute as needed.
- Reconnect: Verify the sensor connector is fully seated on the outdoor control board.
If F5 persists, the compressor temperature sensor or control board may need replacement by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Trane Compressor Temperature Sensor