F3
Tristar Outdoor Pipe Temperature Sensor Fault

Outdoor unit stops and F3 is displayed; may occur in heating mode on heat pump models.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor suction or discharge pipe thermistor, Loose sensor clip on outdoor piping, Weather-damaged sensor wiring, Faulty outdoor PCB sensor input

How to Fix / Troubleshooting

Safety first: Turn off outdoor power and wait for all fans and compressor to stop.

Steps to try:

  • Locate sensor: Look for a small sensor clipped to a refrigerant pipe near the compressor or coil.
  • Check mounting and insulation: Re-secure the sensor and wrap with insulation if missing.
  • Inspect cable: UV and weather can crack insulation; replace if damaged.
  • Measure resistance: Compare to Tristar’s chart. Replace if readings are abnormal.

When to call a technician: If F3 persists, the outdoor PCB may require replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Outdoor Pipe Temperature Sensor
Check Price on Amazon