d1
York Room Temperature Sensor Fault

York ductless AC displays d1 and runs with poor temperature control

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed room thermistor, Sensor out of position behind grille, Broken sensor wiring, Faulty indoor PCB

How to Fix / Troubleshooting

Safety: Turn off power to the indoor unit before removing the front cover.

  • Locate room sensor: On York ductless units, the room thermistor is usually near the air intake grille. Ensure it is properly clipped in place and not touching cold coil surfaces.
  • Inspect wiring: Check the small sensor wires for damage or loose connectors at the PCB.
  • Test thermistor: Measure resistance at room temperature and compare to York's thermistor chart. Replace if readings are open, shorted, or far off spec.
  • Replace PCB if needed: If a known‑good sensor still gives d1, the indoor control board may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Room Temperature Sensor
Check Price on Amazon