P2
York
Low Temperature / Frost Protection
York portable AC displays P2 and shuts off the compressor.
Advertisements
Possible Causes
Evaporator coil icing, Very low room temperature, Restricted airflow, Faulty evaporator temperature sensor
How to Fix / Troubleshooting
Safety: Unplug the unit before cleaning filters or coils.
- Allow ice to melt: Turn the unit off and let it sit for several hours until all ice on the coil has melted.
- Clean air filter: Remove and wash the filter. Ensure intake and exhaust are not blocked.
- Check room temperature: If the room is already very cool, operate in fan mode only or raise the setpoint.
- Sensor check: If P2 occurs frequently under normal conditions, the evaporator sensor may be faulty and should be replaced by a service technician.