Boiler does not respond to the room thermostat; heating stays off even when the thermostat is calling for heat.
Advertisements
Possible Causes
Flat batteries in wireless thermostat, faulty room thermostat, broken control wiring, faulty PCB input
How to Fix / Troubleshooting
Safety: Isolate the power before working on control wiring.
- Check thermostat: Replace batteries in wireless thermostats and ensure the set temperature is above room temperature.
- Check programmer: Confirm heating schedules are active and that the programmer is not set to OFF or HOLIDAY mode.
- Boiler demand light: On many Alpha boilers, a demand indicator shows when there is a call for heat. If this is off despite the thermostat calling, the issue is likely external to the boiler.
- Wiring test (qualified person): At the boiler terminal block, link the room thermostat terminals to simulate a call for heat. If the boiler starts, the external controls or wiring are faulty.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Thermostat
Check Price on Amazon