A12
Beretta Air/Flue System Fault (General)

Boiler displays A12; no ignition; the fan may not start; the display may show a symbol for an air/flue fault.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrectly installed concentric flue, blocked air intake, faulty fan, or a faulty air pressure switch or wiring.

How to Fix / Troubleshooting

Safety: Do not operate the boiler with suspected flue or air intake issues.

  • Check air intake: For concentric flues, ensure the outer ring (air intake) is not blocked by dirt, cobwebs, or building work.
  • Technician – verify flue configuration: Confirm that the flue length, elbows, and terminal type comply with Beretta installation limits.
  • Technician – test fan and pressure switch: Measure fan voltage and check that the air pressure switch closes when the fan runs. Replace faulty components.
  • Inspect wiring: Check connectors between the fan, pressure switch, and PCB for a secure fit and no corrosion.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Fan Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements