H07
Bosch Low Water Pressure Fault

Boiler indicates a low system pressure condition; heating may not start.

Advertisements

Possible Causes

Insufficient water in the heating circuit, Leak in system pipework or radiators, Faulty pressure sensor, Faulty filling loop not closed properly

How to Fix / Troubleshooting

Safety: Allow the system to cool before topping up. Do not over-pressurise the boiler.

Steps:

  • Check pressure gauge: On the front of the Bosch boiler, note the pressure. If below about 1.0 bar when cold, topping up is required.
  • Top up via filling loop: Locate the filling loop (flexible hose or built-in valves). Open the valves slowly until the pressure rises to 1.0–1.5 bar, then close both valves fully.
  • Bleed radiators: Bleed any air from radiators, then recheck pressure and top up again if needed.
  • Check for leaks: Inspect visible pipework, radiators, and the boiler underside for signs of water leakage.

If pressure continues to drop, there may be a hidden leak or faulty expansion vessel; a heating engineer should investigate.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

System Pressure Sensor
Check Price on Amazon

We may earn a commission from links on this page.