A02
Ferroli
Primary Circuit Overheat / Overheat Thermostat Tripped
Boiler lights but then shuts down quickly with error A02; may show signs of overheating such as very hot flow pipe and noisy boiling sounds.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked primary heat exchanger, Failed pump or seized pump, Airlock in primary circuit, Faulty overheat thermostat or NTC sensor
How to Fix / Troubleshooting
Safety first: Turn off power and allow the boiler to cool fully before touching any pipework.
- Check system pressure: On sealed Ferroli systems, ensure the pressure gauge reads around 1.0–1.5 bar when cold. If low, top up via the filling loop according to the manual and bleed radiators.
- Bleed air: Bleed radiators and any manual air vents near the boiler to remove trapped air that can cause localised overheating.
- Verify pump operation (user observation): With the casing on, turn the boiler back on and feel the flow pipe; it should warm gradually, not instantly boil. A loud kettling noise suggests poor circulation.
- Engineer checks:
- Confirm pump is running and not seized; replace the circulation pump if faulty.
- Check and clean the primary heat exchanger for scale or sludge blockage.
- Test the overheat thermostat and flow NTC sensor; replace if readings are out of range.
- Flush the system and add inhibitor to prevent future sludge build-up.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Primary Circulation Pump
Check Price on Amazon