Fondital Short Cycling / Oversized Boiler or Sensor Misreading

Boiler runs for only a short time then stops; radiators never reach the set temperature.

Advertisements

Possible Causes

Flow temperature set too high on Fondital boiler, incorrect NTC sensor readings, poor system volume or missing bypass, pump over-speed causing rapid temperature rise.

How to Fix / Troubleshooting

Safety: No immediate hazard, but efficiency is reduced.

User checks:

  • Lower flow temperature: Reduce the heating flow temperature setting to around 60°C and observe if run times increase.
  • Open more radiators: Ensure enough radiators are open to absorb boiler output.

Technician actions:

  • Check flow and return NTC sensors for accuracy.
  • Verify correct pump speed and adjust if necessary.
  • Install or adjust an automatic bypass valve if required.
  • Review system design versus boiler output and adjust settings (e.g., maximum power) on the Fondital PCB.