Short Cycling / Oversized Boiler or Sensor Misreading
Boiler runs for only a short time then stops; radiators never reach the set temperature.
Advertisements
Possible Causes
Flow temperature set too high on Fondital boiler, incorrect NTC sensor readings, poor system volume or missing bypass, pump over-speed causing rapid temperature rise.
How to Fix / Troubleshooting
Safety: No immediate hazard, but efficiency is reduced.
User checks:
- Lower flow temperature: Reduce the heating flow temperature setting to around 60°C and observe if run times increase.
- Open more radiators: Ensure enough radiators are open to absorb boiler output.
Technician actions:
- Check flow and return NTC sensors for accuracy.
- Verify correct pump speed and adjust if necessary.
- Install or adjust an automatic bypass valve if required.
- Review system design versus boiler output and adjust settings (e.g., maximum power) on the Fondital PCB.