A09
Fondital DHW Temperature Sensor / Modulation Fault

Boiler displays A09; domestic hot water temperature is unstable or excessively hot.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty DHW NTC sensor on Fondital plate heat exchanger, Scaled or partially blocked DHW plate heat exchanger, Sticking gas valve not modulating correctly, Incorrect sensor wiring

How to Fix / Troubleshooting

Safety: Risk of scalding. Test hot water carefully and avoid opening taps to their maximum until the issue is resolved.

User checks:

  • Flow rate: Open hot taps moderately instead of fully to see if the temperature stabilizes.
  • Reset: Reset the boiler once. If A09 returns, professional service is needed.

Technician actions:

  • Measure the resistance of the DHW NTC sensor and compare it with Fondital temperature/resistance tables.
  • Descale or replace the DHW plate heat exchanger if restricted by limescale.
  • Check gas valve modulation via flue gas analysis and adjust or replace the gas valve if necessary.
  • Inspect the wiring between the DHW NTC and the main PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements