A15
Fondital Room Thermostat / External Control Fault

Boiler displays A15, no response to thermostat demand, heating symbol may flash

Advertisements

Possible Causes

Open circuit in room thermostat wiring, Incorrect configuration of Fondital control terminals, Faulty external thermostat or chronothermostat, Main PCB input fault

How to Fix / Troubleshooting

Safety: Isolate power before touching any control wiring. Low-voltage circuits can still be damaged by short circuits.

User checks:

  • Thermostat settings: Ensure the room thermostat or Fondital remote control is set to heating mode and a temperature above room temperature.
  • Batteries: Replace batteries in wireless thermostats or remote controls.
  • Manual mode: If available, set the boiler to manual or test mode to see if it can heat independently of the thermostat.

Technician actions:

  • Check continuity of the room thermostat wiring to the boiler terminals.
  • Verify correct configuration of the Fondital control board jumpers for external controls.
  • Test the room thermostat / chronothermostat and replace if defective.
  • Check the main PCB input circuit for the thermostat.