A15
Fondital
Room Thermostat / External Control Fault
Boiler displays A15, no response to thermostat demand, heating symbol may flash
Advertisements
Possible Causes
Open circuit in room thermostat wiring, Incorrect configuration of Fondital control terminals, Faulty external thermostat or chronothermostat, Main PCB input fault
How to Fix / Troubleshooting
Safety: Isolate power before touching any control wiring. Low-voltage circuits can still be damaged by short circuits.
User checks:
- Thermostat settings: Ensure the room thermostat or Fondital remote control is set to heating mode and a temperature above room temperature.
- Batteries: Replace batteries in wireless thermostats or remote controls.
- Manual mode: If available, set the boiler to manual or test mode to see if it can heat independently of the thermostat.
Technician actions:
- Check continuity of the room thermostat wiring to the boiler terminals.
- Verify correct configuration of the Fondital control board jumpers for external controls.
- Test the room thermostat / chronothermostat and replace if defective.
- Check the main PCB input circuit for the thermostat.