Glow-worm Frozen Condensate Discharge

Condensate pipe repeatedly freezing in cold weather, boiler stops working

Advertisements

Possible Causes

Condensate pipe run externally for a long distance, Small bore pipe (less than 32mm), Inadequate insulation, Poor fall on pipe.

How to Fix / Troubleshooting

Safety: Do not use boiling water on plastic pipes. Take care on icy ground.

  • Locate frozen section: Find the external condensate pipe (usually white or grey plastic) and identify any bulges or ice.
  • Thaw gently: Pour warm (not boiling) water over the frozen section or use a warm cloth to thaw the ice.
  • Reset boiler: Once thawed and condensate can flow, reset the boiler following the manual.
  • Engineer tasks:
    • Increase pipe size to at least 32mm externally.
    • Improve pipe insulation and reduce the external run length.
    • Adjust the pipe fall to ensure good drainage.

Improving condensate pipe installation will reduce recurrence in future cold spells.