Condensate pipe repeatedly freezing in cold weather, boiler stops working
Advertisements
Possible Causes
Condensate pipe run externally for a long distance, Small bore pipe (less than 32mm), Inadequate insulation, Poor fall on pipe.
How to Fix / Troubleshooting
Safety: Do not use boiling water on plastic pipes. Take care on icy ground.
- Locate frozen section: Find the external condensate pipe (usually white or grey plastic) and identify any bulges or ice.
- Thaw gently: Pour warm (not boiling) water over the frozen section or use a warm cloth to thaw the ice.
- Reset boiler: Once thawed and condensate can flow, reset the boiler following the manual.
- Engineer tasks:
- Increase pipe size to at least 32mm externally.
- Improve pipe insulation and reduce the external run length.
- Adjust the pipe fall to ensure good drainage.
Improving condensate pipe installation will reduce recurrence in future cold spells.