A03
Immergas
Low System Pressure Lockout
Boiler displays A03, water pressure too low; boiler will not start.
Advertisements
Possible Causes
Loss of water from system, Leak in radiators or pipework, Faulty pressure sensor, User has not topped up system
How to Fix / Troubleshooting
Safety: Do not overfill the system. Typical cold pressure is around 1.0–1.5 bar; check your Immergas manual.
- Top up pressure: Locate the filling loop under the boiler. Open the valves slowly until the pressure gauge reaches the recommended value, then close both valves.
- Bleed air: Bleed radiators and re-check pressure, topping up again if needed.
- Check for leaks: Inspect radiators, valves, and visible pipework for signs of water. Repair leaks promptly.
- Sensor check: If the gauge shows correct pressure but A03 persists, the pressure sensor may be faulty and should be replaced by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Filling Loop (User Operation) / Water Pressure Sensor
Check Price on Amazon