3
Intergas Pre-Purge / Ignition Sequence Not Completing

Boiler shows code 3, fan running but no ignition, boiler does not fire

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty ignition electrode or lead, Gas valve not opening, Blocked flue or air intake, Faulty PCB ignition control

How to Fix / Troubleshooting

Warning: Ignition and gas valve checks involve gas and combustion. Do not remove the boiler case or attempt internal repairs unless you are a Gas Safe registered engineer.

  • Reset the boiler: Turn the boiler off at the control panel, wait 10 seconds, then turn it back on. If code 3 persists and the boiler never progresses to flame, note any error codes that follow.
  • Check gas supply: Ensure the gas meter is on and that other gas appliances (e.g. hob) work. If there is no gas supply, contact your gas supplier.
  • Check flue terminal: From outside, visually inspect the flue terminal for obstructions (leaves, nests, debris). Do not insert objects into the flue. Clear any obvious external blockage.
  • Power cycle: Isolate power at the fused spur for 30 seconds, then restore. Sometimes the PCB will reset and complete ignition.
  • Call an engineer: If the boiler repeatedly stalls at code 3, a Gas Safe engineer must check the ignition electrode, flame sensor, gas valve operation, fan speed, and flue integrity.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Ignition Electrode
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements