A12
IVT Communication Fault with Room Controller / Bus Error

Boiler displays A12, no response to thermostat or control signals.

Advertisements

Possible Causes

broken OpenTherm/Bus wiring, incorrect controller configuration, faulty room thermostat, PCB communication interface fault

How to Fix / Troubleshooting

Safety: Turn off the power before working on control wiring.

Steps:

  • Check that the room controller or thermostat has power (batteries or mains supply).
  • Inspect the low-voltage control cable between the IVT boiler and controller for damage or loose terminals.
  • Ensure the polarity and terminals match the IVT wiring diagram (e.g., BUS+, BUS−, or OT1, OT2).
  • Reset both the boiler and controller according to their respective manuals.
  • If communication is still lost, a technician should test with a known-good controller and replace the faulty device or PCB interface.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Room Controller / Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements