E25
Keston
Low Flow / Minimum Flow Rate Fault
Boiler displays E25; CH flow temperature rises too quickly at low load.
Advertisements
Possible Causes
All TRVs closed, Bypass not fitted or set, Pump speed too low, Blocked system filter
How to Fix / Troubleshooting
Safety: Surfaces may be hot. Allow the system to cool before adjusting valves.
User checks:
- Ensure at least a few radiators have their thermostatic radiator valves (TRVs) fully open.
- Check that any manual bypass radiator (usually in the hall or bathroom) is open.
Engineer checks:
- Verify that a suitable automatic bypass valve is installed and correctly set for the Keston boiler.
- Check and clean any system filter or strainer on the return pipework.
- Increase pump speed if set too low, ensuring noise and flow remain acceptable.
- Advise on correct TRV usage to maintain minimum flow through the boiler.