F8
Peerless Condensate Drain Blocked

Boiler displays F8 and may indicate 'Condensate Fault'.

Advertisements

Possible Causes

Clogged condensate trap, a kinked condensate hose, a frozen condensate line, or a failed condensate pump (if used)

How to Fix / Troubleshooting

Safety first: Turn off power. Condensate is mildly acidic; wear gloves and eye protection.

Steps:

  • Locate condensate trap: On condensing Peerless boilers, find the plastic trap at the bottom of the heat exchanger or flue collector.
  • Clean trap: Remove the trap and flush it with clean water to remove sludge and debris.
  • Inspect hoses: Ensure condensate hoses are not kinked and slope continuously to the drain.
  • Check condensate pump: If a pump is used, verify it runs and discharges water. Clean or replace if stuck.
  • Reassemble and test: Reinstall the trap, restore power, and reset the boiler.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate trap
Check Price on Amazon

We may earn a commission from links on this page.