E160
Potterton Fan Fault / No Fan Feedback

Boiler displays E160, a fan-related error, and the boiler will not fire.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Fan not running, fan speed sensor failure, loose fan wiring, PCB fan control failure.

How to Fix / Troubleshooting

Safety first: Isolate power before accessing the fan compartment.

User checks:

  • Reset the boiler and listen for the fan starting; report any unusual noises.

Engineer checks:

  • Check for correct voltage at the fan terminals when a demand is present.
  • Inspect the fan blades for obstruction and check that the shaft spins freely.
  • Test the fan speed feedback signal and wiring continuity.
  • Replace the fan assembly if it fails to start or provide feedback; if the fan is OK, suspect the PCB.

Fan faults must be rectified before the boiler can operate safely.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Fan Assembly
Check Price on Amazon