A15
Riello
Blocked or Frozen Condensate Drain
Boiler shows condensate fault, often during cold weather; the boiler will not fire.
Advertisements
Possible Causes
Frozen external condensate pipe, blocked condensate trap, incorrectly sized or sloped condensate pipework, debris in trap.
How to Fix / Troubleshooting
Safety: Condensate is mildly acidic. Wear gloves and eye protection when handling. Isolate power before removing the trap.
- Check external pipe: Inspect the external condensate pipe for ice. If frozen, pour warm (not boiling) water over the pipe to thaw. Insulate the pipe to prevent recurrence.
- Empty and clean trap: Remove the condensate trap beneath the boiler, empty it into a suitable container, and rinse out any debris. Refit securely, ensuring seals are in place.
- Check pipe fall: Ensure the condensate pipe slopes continuously downward with no sags that can trap water.
- Reset boiler: After clearing the blockage, reset the boiler and confirm normal operation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Trap
Check Price on Amazon
We may earn a commission from links on this page.