F22
Saunier Duval
Dry Fire / Low Water Content Protection
Boiler displays F22 and will not fire; pressure gauge often near zero.
Advertisements
Possible Causes
Very low or no water in system, faulty pressure sensor, airlock preventing water flow, recent draining without proper refill.
How to Fix / Troubleshooting
Safety first: Ensure the boiler is cool before adding water.
Steps to check:
- Check the pressure gauge. If below 0.5 bar, repressurise via the filling loop to 1.2–1.5 bar.
- Bleed radiators and top up again if pressure drops.
- Reset the boiler and check for normal operation.
- If the gauge shows correct pressure but F22 remains, the pressure sensor may be faulty and require replacement.
Warning: Do not run the boiler with no water; this can severely damage the heat exchanger.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Pressure Sensor
Check Price on Amazon