E08
Triangle Tube DHW Temperature Sensor Fault

Boiler shows E08; the domestic hot water (DHW) temperature reading is incorrect or missing.

Advertisements

Possible Causes

Failed DHW NTC sensor on the indirect tank or plate heat exchanger; loose sensor wiring; sensor not fully inserted into the well; control board DHW sensor circuit fault.

How to Fix / Troubleshooting

Safety: Turn off power and close water valves to the indirect tank or DHW circuit if necessary.

  • Step 1 – Locate the DHW sensor: On Triangle Tube boilers with an indirect tank, the DHW sensor is usually inserted into a dry well on the tank. On combi models, it may be mounted on the DHW outlet or plate heat exchanger.
  • Step 2 – Check connection: Reseat the sensor connector and inspect the cable for damage.
  • Step 3 – Confirm insertion: Make sure that the sensor is fully inserted into the well and secured with the clip or screw so it can accurately sense tank temperature.
  • Step 4 – Reset: Restore power and reset the boiler. If E08 remains, the sensor is likely defective.
  • Replace sensor: Remove the old DHW NTC sensor and install a new Triangle Tube-compatible sensor. No water should leak if it is a dry-well type.
  • Technician involvement: If the error persists, the control board or wiring harness may need professional diagnosis.