Possible Causes
Too much detergent in the solution, use of non-carpet-cleaner detergent, dirty water tank overfilled with foam, blocked foam filter.
How to Fix / Troubleshooting
Safety: Unplug the appliance if foam reaches electrical areas.
- Stop and empty tank: Remove and empty the dirty water tank. Rinse out the foam thoroughly.
- Rinse filters: Wash the foam filter and any mesh screens to remove detergent residue.
- Use correct detergent: Refill with the recommended Morphy Richards carpet shampoo at the correct dilution. Avoid household cleaners that foam heavily.
- Monitor fill level: Do not allow the dirty water tank to fill beyond the max line; excessive foam can trigger premature shutoff or leaks.
Advertisements
Repair Difficulty
Very Easy
1/5