E12
Cecotec Filter Detection / Filter Not Installed or Saturated

Vacuum shows E12 and suction is reduced; the unit may pulse on and off.

Advertisements

Possible Causes

Pre-motor filter missing or not seated correctly, HEPA filter not locked in place, Filter sensor switch not engaged, Filter extremely clogged causing sensor to trip

How to Fix / Troubleshooting

Safety first: Remove the battery before opening the dust bin or filter compartments.

  • Step 1 – Verify filter installation: Remove and reinstall the pre-motor and HEPA filters, ensuring they are oriented correctly and fully seated. Listen for any locking clicks.
  • Step 2 – Clean filters: Tap filters gently to remove dust. If washable per Cecotec manual, rinse with water and allow to dry completely (24 hours) before reinstalling.
  • Step 3 – Check filter doors: Ensure all filter covers and doors are fully closed. Some models have micro-switches that detect open covers.

If E12 persists with clean, correctly installed filters, the filter detection switch or sensor may be faulty, requiring service.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Pre-motor filter, HEPA filter, and filter detection switch