F6 E3
Bauknecht Water Distribution / Diverter Valve Fault

Dishwasher shows F6 E3 and may stop during filling or washing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck diverter valve, Blocked water channels in distribution system, Faulty diverter motor, Wiring issue to diverter

How to Fix / Troubleshooting

Safety first: Disconnect power and water.

  • Check spray arms: Ensure spray arms are clean and can rotate freely; blockages can affect water distribution.
  • Access diverter: On many Bauknecht models, a diverter valve is integrated into the circulation pump or sump. Remove the base panel to locate it.
  • Inspect for obstructions: Check the diverter mechanism for debris or scale preventing movement. Clean carefully.
  • Test motor: With a multimeter, check the diverter motor coil for continuity. Replace the diverter assembly if open or seized.
Advertisements

Video Guide

Repair Difficulty

Hard 4/5

Required Part

Diverter Valve Assembly
Check Price on Amazon