E18
Bertazzoni
Insufficient Water Level / Short Fill
Dishwasher displays E18; the unit fills only partially or stops with a low water level in the tub.
Advertisements
Possible Causes
Partially clogged inlet valve filter, Low household water pressure, Kinked inlet hose, Faulty flow meter undercounting water
How to Fix / Troubleshooting
Safety first: Disconnect the power and turn off the water.
- 1. Clean inlet filter: Shut off the water, disconnect the inlet hose at the valve, and remove and clean the small mesh filter.
- 2. Check hose routing: Ensure the inlet hose is not kinked or pinched behind the dishwasher.
- 3. Verify water pressure: Confirm that other fixtures have good flow. If the pressure is low, consult a plumber.
- 4. Flow meter: If the physical water level looks normal but E18 appears, the flow meter may be miscounting and should be cleaned or replaced.
After cleaning and correcting supply issues, run a test cycle to confirm normal filling.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Inlet Valve Assembly