Classeq Inconsistent Chemical Dosing

Classeq dishwasher chemical dosing seems inconsistent; sometimes too much, sometimes too little detergent.

Advertisements

Possible Causes

Worn peristaltic pump tube, Air ingress in suction line, Incorrect dosing time settings, Blocked injector or non-return valve

How to Fix / Troubleshooting

Safety first: Wear appropriate PPE when handling chemicals. Isolate power before servicing pumps.

  • Inspect pump tube: On peristaltic detergent and rinse aid pumps, check the flexible tube for flattening, cracks, or hardness. Replace if worn.
  • Eliminate air leaks: Ensure suction tubes are fully submerged and connections are tight. Replace brittle tubing.
  • Clean injectors: Remove and clean chemical injectors and non-return valves to ensure free flow.
  • Recalibrate dosing: Using Classeq's procedure, set and verify dosing times to achieve the correct concentration.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Detergent Dosing Pump Tube
Check Price on Amazon