Possible Causes
Worn peristaltic pump tube, Air ingress in suction line, Incorrect dosing time settings, Blocked injector or non-return valve
How to Fix / Troubleshooting
Safety first: Wear appropriate PPE when handling chemicals. Isolate power before servicing pumps.
- Inspect pump tube: On peristaltic detergent and rinse aid pumps, check the flexible tube for flattening, cracks, or hardness. Replace if worn.
- Eliminate air leaks: Ensure suction tubes are fully submerged and connections are tight. Replace brittle tubing.
- Clean injectors: Remove and clean chemical injectors and non-return valves to ensure free flow.
- Recalibrate dosing: Using Classeq's procedure, set and verify dosing times to achieve the correct concentration.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Detergent Dosing Pump Tube
Check Price on Amazon