E20
Meiko Exhaust / Condenser System Fault

E20 displayed; exhaust or steam condenser fault on Meiko hood-type or conveyor models with heat recovery.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser coil, Failed exhaust fan, Faulty exhaust temperature sensor, Blocked condensate drain

How to Fix / Troubleshooting

Safety first: Disconnect power and allow the machine and condenser to cool. Wear gloves; surfaces may be sharp and greasy.

  • Clean condenser surfaces: Access the steam condenser or heat recovery unit. Remove panels and clean fins and channels of grease and scale using approved cleaning agents.
  • Check exhaust fan operation: Verify that the exhaust fan runs when commanded. Listen for bearing noise or imbalance. Measure motor resistance and replace the fan assembly if defective.
  • Inspect exhaust temperature sensor: Locate the sensor in the exhaust duct. Check resistance and wiring. Replace if readings are out of range.
  • Clear condensate drain: Ensure the condensate drain from the condenser is not blocked. Clean the trap and tubing to prevent water backing up into the unit.
  • Test system: After cleaning and repairs, run the machine and monitor exhaust performance. If E20 persists, further diagnostics by a Meiko technician are recommended.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Exhaust Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements