filter
Ariston Lint Filter / Airflow Restriction Warning

Display shows FILTER or filter icon; dryer stops or warns at the end of the cycle.

Advertisements

Possible Causes

Clogged lint filter, Blocked internal lint channel, Restricted exhaust duct

How to Fix / Troubleshooting

Safety first: Unplug the dryer before removing rear panels or internal ducts.

  • Clean lint filter: Remove the main lint filter and clean it thoroughly under running water if coated with fabric softener residue. Dry completely before refitting.
  • Inspect filter housing: Use a vacuum with a narrow nozzle to remove lint from the filter housing and internal channel.
  • Check exhaust duct: For vented models, disconnect the exhaust hose and clean it end‑to‑end. Ensure the wall vent flap moves freely.
  • Reset warning: After cleaning, run a short cycle. The filter warning should clear automatically on most Ariston models.
Advertisements

Repair Difficulty

Very Easy 1/5
Advertisements