Hotpoint-Ariston
Water Level Sensor / Float Switch Fault
Water tank full indicator is on and dryer stops, but the tank is empty.
Advertisements
Possible Causes
Stuck float in condensate tank housing, Faulty float switch, Blocked sensor chamber, Wiring fault to level sensor
How to Fix / Troubleshooting
Safety first: Disconnect mains power before accessing the tank housing.
- Remove and inspect tank: Take out the water tank and inspect the housing for a float mechanism. Clean any lint or slime that may be causing it to stick.
- Check float movement: Ensure the float moves freely up and down. Free it if stuck.
- Test switch: If accessible, test the float switch with a multimeter for correct open/closed operation as the float moves.
- Wiring check: Inspect the wiring from the float switch to the control board for damage or loose connections.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Float Switch / Level Sensor
Check Price on Amazon