E13
LG
Steam Generator / Water Supply Error
LG steam dryer shows E13; steam function does not operate correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
No water supply to steam valve, Clogged steam inlet filter, Failed steam valve, Faulty steam generator sensor
How to Fix / Troubleshooting
Safety first: Unplug the dryer and close the water supply valve to the steam function.
Steps:
- Check water supply: Ensure the water supply valve feeding the dryer is open and the hose is not kinked.
- Clean inlet filter: Turn off water, disconnect the inlet hose at the dryer, and remove the small filter screen inside the valve. Rinse debris and reinstall.
- Inspect steam hose: Check internal steam hoses for kinks or leaks (access via top panel).
- Valve and generator: If water supply is good but E13 persists, the steam valve or generator assembly may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Steam Inlet Valve
Check Price on Amazon
We may earn a commission from links on this page.