E51
Zanussi
Motor Triac Short Circuit on Control Board
Zanussi dryer shows E51 and may trip the breaker or fail to start the motor.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted motor triac on PCB, Shorted motor windings, Damaged motor wiring harness
How to Fix / Troubleshooting
Safety first: Disconnect from mains. PCB and motor testing should only be done if you are competent with electrical diagnostics.
- 1. Visual inspection: Remove the top panel and locate the main control board. Look for burn marks or damaged components near the motor control area.
- 2. Check motor wiring: Inspect the harness from the PCB to the motor for chafing, burns, or shorts to the cabinet. Repair any damaged wiring.
- 3. Motor test: Disconnect the motor and test its windings for continuity and insulation resistance. A shorted motor can cause the triac to fail.
- 4. PCB replacement: If the triac is visibly damaged or tests faulty, the entire control board is typically replaced as a unit. Use a genuine Zanussi board with the correct part number.
- 5. Professional repair recommended: Because this involves mains-level electronics and potential board-level faults, it is strongly recommended to use a qualified technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements