E006
ABB
Proximity / Plug Detection Failure
Display shows E006; charger does not recognize that a vehicle is connected.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken proximity (PP) conductor in cable, Damaged resistor network in connector, Faulty proximity detection circuit on control board, Bent or contaminated pins in vehicle connector
How to Fix / Troubleshooting
Note: Proximity detection ensures the charger knows a plug is inserted and can limit current based on cable rating.
- Inspect connector pins: Examine the Type 2/Type 1 plug for bent, recessed, or corroded pins, especially the PP (proximity) pin. Clean gently with electrical contact cleaner if dirty.
- Check cable strain relief: Look for kinks or sharp bends near the charger housing and connector where the PP conductor may have broken internally.
- Wiggle test: With the charger powered and vehicle connected, gently move the cable near both ends. If the error appears or disappears intermittently, the cable assembly is likely faulty.
- Replace cable assembly: If proximity wiring is suspected, replace the ABB OEM tethered cable assembly. Do not attempt to splice or repair the PP conductor.
- Control board check: If a new cable does not resolve E006, the proximity detection circuit on the main control board may be defective and require board replacement.