E09
Grizzl-E Surge Protection / MOV Failure

Charger LEDs show error; unit may not power up fully; occurs after lightning storm or power surge

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Metal‑oxide varistor (MOV) damaged by surge, Burned surge protection components on control board, Overvoltage event on supply line, Inadequate surge protection upstream

How to Fix / Troubleshooting

Safety: Turn OFF the breaker and verify no voltage is present before opening the unit.

  • Inspect for surge damage: Remove the cover and look near the input terminals for MOVs or surge modules. Signs of failure include cracking, charring, or a burnt odor.
  • Check for collateral damage: Examine the main control board for burnt traces or components.
  • Do not bypass surge parts: Never remove or bypass MOVs to clear the error; this removes critical protection.
  • Resolution: Replace the damaged surge protection components or the entire main control board assembly. Consider adding an external whole‑home surge protector at the panel.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Surge Protection MOV Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements