E16
JuiceBox Load Sharing Communication Fault

Charger displays E16 load sharing or dynamic load management error when used in a group installation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected RS-485 or CAN bus wiring between JuiceBox units, Incorrect load sharing configuration in app, Address conflict between chargers, Failed communication transceiver on control board

How to Fix / Troubleshooting

Safety first: Turn off power to all linked chargers before modifying communication wiring.

  • Verify wiring topology: Confirm that the load sharing communication cable (RS-485/CAN) is daisy-chained correctly between units and that polarity (A/B or CAN-H/CAN-L) is consistent.
  • Check termination: Ensure that termination resistors are installed only at the ends of the bus, per JuiceBox installation guidelines.
  • Review configuration: In the management app or web portal, verify that each charger has a unique address/ID and that they are assigned to the same load group with correct maximum aggregate current.
  • Isolate the fault: Disconnect all but two chargers and test. Add units one by one to identify if a specific charger is causing E16. That unit may have a failed communication transceiver on its main board.
  • Board repair: If one unit consistently triggers E16 when added, its main control board or communication daughterboard likely needs replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Load Sharing Communication Harness