E08
Mennekes
Phase Loss / Phase Sequence Error
E08 displayed; charger indicates phase error and refuses to start (on 3-phase installations).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Missing phase at supply, Incorrect phase sequence (L1/L2/L3 swapped), Loose phase conductor in terminal block, Faulty phase monitoring circuit
How to Fix / Troubleshooting
Safety first: Only a qualified electrician should work on 3-phase connections. Isolate the supply before opening the terminal compartment.
- Measure phase voltages: Verify presence of all three phases and correct line-to-line voltages at the charger’s input terminals.
- Check phase order: Some Mennekes chargers monitor phase rotation. Confirm that L1, L2, and L3 are connected according to the installation manual. Correct any miswiring.
- Tighten terminals: With power OFF, tighten all phase conductors to the specified torque. Look for signs of overheating or discoloration.
- Phase monitor circuit: If supply is correct and wiring is tight, the internal phase monitoring circuit on the main PCB or a dedicated phase monitor module may be defective and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Phase Monitoring Module / Main Control PCB
Check Price on Amazon