E014
Rivian
Line Phase Loss or Severe Imbalance
Rivian charger shows E014; the app indicates ‘Phase loss / line imbalance’ on a split-phase installation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
One leg (L1 or L2) open at the breaker or panel, loose conductor at the charger terminal block, failed internal fuse or thermal link on one line, utility supply issue on one phase.
How to Fix / Troubleshooting
Safety first: This is a mains wiring issue. If you are not trained, call an electrician.
- Step 1 – Breaker inspection: Confirm that the double-pole breaker handle is not partially tripped. Reset it fully OFF then ON.
- Step 2 – Panel wiring: With the breaker OFF, remove the panel cover and verify that both legs of the breaker are connected to hot bus bars and that both conductors are firmly attached.
- Step 3 – Charger terminal block: With power OFF and the charger cover removed, check that both L1 and L2 conductors are secure in the terminal block and show no signs of overheating.
- Step 4 – Voltage test: A qualified person should measure L1–L2 at the charger input; if one leg is missing or significantly low, contact the utility or replace the breaker.
If wiring and supply are correct, an internal line-sensing circuit or fuse may have failed and the charger will need professional service.