Brandt
Unstable Temperature Control
Freezer temperature fluctuates widely; sometimes too warm, sometimes too cold
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty temperature sensor, Poor air circulation due to blocked vents, Control board logic fault, Ambient temperature outside design range
How to Fix / Troubleshooting
Safety first: Unplug the freezer before accessing sensors or panels.
Steps:
- Check loading: Avoid blocking air vents with packages. Allow space for air to circulate.
- Verify ambient conditions: Ensure the freezer is installed in a room within the temperature range specified by Brandt.
- Test temperature sensor: Measure NTC resistance and replace if unstable or out of spec.
- If sensor is good: Replace the main control board to correct erratic control.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Temperature Sensor / Main Control Board