Brandt Lighting Circuit Failure

Interior light not working but freezer otherwise cools normally

Advertisements

Possible Causes

Burned-out LED module or bulb, Faulty door switch, Loose light connector, Failed light driver on control board

How to Fix / Troubleshooting

Safety first: Unplug the freezer before replacing any light components.

Steps:

  • Check door switch: If the light never comes on, test the door switch for continuity. Replace if faulty.
  • Replace light module: On LED-equipped Brandt freezers, remove the light cover and swap the LED module with a new one of the same type.
  • Inspect wiring: Ensure the light connector is firmly seated and wires are intact.
  • If new light and switch do not work: The control board's light circuit may be defective and require replacement.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

LED Light Module / Door Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements