Galanz Inaccurate Temperature Control

Freezer is cold but temperature fluctuates widely; sometimes too warm, sometimes too cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Aging or drifting thermostat, Intermittent temperature sensor connection, Main control board logic fault, Freezer overloaded or vents blocked

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing controls or sensors.

  • Use a thermometer: Place an accurate freezer thermometer in the center of the compartment and log temperatures over 24–48 hours to confirm fluctuations.
  • Check loading and airflow: Avoid overpacking the freezer. Keep vents clear and leave space between items for air circulation.
  • Inspect sensor connections: For electronic models, access the cabinet sensor connector and the main control board. Reseat connectors to eliminate intermittent contact.
  • Replace suspect components: If a mechanical thermostat is erratic, replace the Galanz thermostat. If sensors and wiring are good but control remains unstable, the main control board may need replacement.
  • Allow stabilization: After any adjustment or part replacement, allow at least 24 hours for temperatures to stabilize before re-evaluating.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Thermostat or Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements