Hisense Continuous Run / Short Cycling Control

Freezer runs continuously without shutting off, even when interior is very cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Leaky door gasket causing warm air infiltration, Misplaced or faulty temperature sensor, Control board not recognizing setpoint, Heavy frost restricting airflow

How to Fix / Troubleshooting

Safety first: Unplug the freezer before adjusting internal components.

  • Inspect door gasket: Look for gaps, tears, or hardened sections. Close the door on a sheet of paper; if it pulls out easily, the seal is weak. Replace the gasket if needed.
  • Check sensor placement: Ensure the cabinet temperature sensor is properly mounted and not touching the evaporator or walls directly, which can mislead the control.
  • Defrost if frosted: If you see frost on the rear panel or shelves, fully defrost the unit to restore airflow.
  • Verify temperature: Use a thermometer to confirm the actual temperature. If it is below -20°C (-4°F) and the unit still runs, the control may be faulty.
  • Replace control components: Replace the temperature sensor first. If continuous running persists, the main control board or thermostat may need replacement.

Continuous running increases energy use and wear; if basic checks do not resolve it, seek professional service.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Gasket
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements