E3
Hitachi Quick-Freeze Function Control Error

Freezer shows E3 and may not enter quick-freeze or power-freeze mode

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty quick-freeze button on control panel, Software error in main control PCB, Damaged wiring between panel and main PCB

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the control panel.

  • Test quick-freeze button: Press the button and observe if the indicator LED responds. If not, suspect the panel.
  • Inspect panel wiring: Remove the control panel and check the ribbon cable for damage or loose connections.
  • Power reset: Unplug the freezer for 10 minutes and reconnect to clear temporary software errors.
  • Replace control panel: If the button is unresponsive and wiring is intact, replace the Hitachi control panel PCB.
  • Main PCB: If the panel works but the compressor does not respond to quick-freeze commands, the main control PCB may be faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Panel PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements